17. OPERATION THEATRE UNITS: Sl. No. Year Out patient In patient 1 2006-07 5,73,049 87,670 2 2007-08 6,06,677 88,870 3 2008-09 6,18,735 91,311
(Number-13 and Tables-19)
Casualty OT, Cardiology OT, CTVS OT, Dental OT, ENT OT, Main OT, New Main OT, Neurosurgery OT, Obst. & Gynecology OT, Ophthalmology OT, Orthopedic OT,Plastic Surgery OT, Urology OT
Arrangement: Distributed amongst Units Heads
Equipments: Bowels apparatus, Monitoring Devices (including Anesthesia equipment), Diathermy Ventilatory equipments, ABG system, Surgical Instruments.
18.INTENSIVE CARE UNITS:
No. of Beds Specialized equipments in each
ICU - 20 Ventilators, Pulse Oxymeter, ECG
ICCU- 8 Capnometer, Syringe pump
Surgical intensive Recovery Room of CTVS & Neurosurgery Care area
Pediatrics Intensive NICU-2: Ventilator,
Pulse Oxymeter care area
Labour Room
Clean with number of beds-12
Septic with number of beds -8
19. CENTRAL STERLISATION SERVICES:
(a) Exclusive or with substerilisation centers also: Exclusive
(b) Equipment scope and in-service arrangement:
(i) 42lb H.P. Sterilizer -1
(ii) 300 S Vapour AX Boiler -1
(iii) 21 SR H.P. HVTS Sterilizer -1
(iv) Ekectruc G, O, Sterilizer -1
(c) Volume of work/ day - 40 to 60 drums/ day
(d) Arrangement of sterilization of mattresses and blankets
20. CENTRAL LAUNDRY:
(a) Equipment: Mechanized - Bulk washing machine, Washing Machine Hydro extractor, Flat Hydro extractors and Rowley Steam Press, Steam press drying chamber and Manual.
(b) Volume of work -1600 clothes per day.
21. NUMBER OF PATIENTS (O.P.D. AND INDOOR):
Outdoor -Average Daily Patient Attendance:
Old patients-190 + New patients-1543=1733
Indoor - Annual Admissions - 96, 325 Approximate. However the data of out patient and inpatient for current 3 years is as per below.
22. HOSPITAL BEDS:
|
Sl. No. |
Department |
Beds |
|
1 |
Medicine: (Gen.Bed-146, ICU-04) |
150 |
|
2 |
Cardiology: (Gen.Bed-36, ICU-08) |
44 |
|
3 |
Endocrinology |
07 |
|
4 |
Gastroenterology |
18 |
|
5 |
Haematology |
05 |
|
6 |
Nephrology |
04 |
[ : Information available in this manual was last accses on ]
While all efforts have been made to make this website as authentic as possible, I & PR deptt. and Luminous Infoways will not be responsible for authentication of proactive disclosure and annual report. Respective department and Public Authority is responsible for their information. Users are advised to verify/check any information with the relevant department(s) and/or other source(s), before acting on the information provided in the Portal.